MIDI Program Change and Control Change Enable
You can select whether HEX responds to MIDI Program Change (PC),
Control Change (CC), both message types, or none.
NOTE: When using Voodoo Lab Ground Control Pro, you must disable
both PC and CC.
The default is both PC and CC are disabled.
1.) Apply power while holding down button #3. LED #3 will flash until you release the button.
2.) Press buttons #1 and #2 according to this table.
MIDI Message Type LED #1 LED #2
None* OFF OFF
PC only ON OFF
CC only OFF ON
Both PC and CC ON ON
*None is the correct setting for Voodoo Lab Ground Control Pro
only.
3) Remove power when finished.
Select Control Change Numbers
Each MIDI Control Change (CC) message includes a controller number, which specifies which HEX loop to turn on or off.
You can select from four different groups of CC numbers.
The default group is CC numbers 80-83, which means that 80 controls switch #1, 81 controls switch #2, 82 controls
switch #3, and 83 controls switch #4.
Here’s how you select which CC numbers HEX will respond to:
1.) Apply power while holding down button #4. LED #4 will flash until you release
the button.
2.) Press buttons 1, 2 and 3 according to this table.
CC# LED#1 LED#2 LED#3 GCX Loops
80-83 OFF OFF OFF GCX#1 Loops 1-4
84-87 OFF OFF ON GCX#1 Loops 5-8
88-91 OFF ON OFF GCX#2 Loops 1-4
92-95 OFF ON ON GCX#2 Loops 5-8
64-67 ON OFF OFF GCX#3 Loops 1-4
68-71 ON OFF ON GCX#3 Loops 5-8
56-59 ON ON OFF GCX#4 Loops 1-4
60-63 ON ON ON GCX#4 Loops 5-8
3) Remove power when finished.